Measuring range: 0-2000cm
Maximum water level variability: 60cm / min
Resolution: 0.1cm
Measurement accuracy: ± 2cm (10m range);When
more than 10 m, ± (2cm ± 0.2% F • S)
Display: LED digital display
Mechanical parameters
Working round: 32cm
Measuring cable: Φ1mm stainless steel cable
Float diameter: To be determined
Output form:
Current output, voltage output, RS485 output three,selected one
RS485 interface: MODBUS protocol
Current type: 4 ∼ 20mA analog signal output
Voltage: 1~5V
Use environment
Ambient temperature: 0 ℃ ∼ 85 ℃
Relative humidity: <90% (40℃)
Size: 132 × 132 × 115
Voltage
Power supply 5 ∼ 20VDC
Rated voltage: 12V Rated current: 90mA Rated power: 1W
Anti surge patent | Resistance to strong electromagnetic interference | Gray code transmission | Power off memory function |
The instrument adopts the national new anti-surge patented technology design, In the surge environment, |
Strong electromagnetic interference can interfere with signal transmission on the daily monitoring of adverse effects. Anti-strong electromagnetic interference system is very good to solve this problem, to ensure that data transmission more timely, can continue to work in harsh environment. |
Gray code, also known as binary cycle code. Different range of instruments using different lengths of cable can output 1024 to 4096 groups of different coding, can be used to measure 10 to 40 meters water level amplitude, to ensure that the working distance while ensuring the accuracy of transmission. |
Power off memory function can save data very well. Coupled with no temperature, zero drift, can be effective to ensure that data in harsh environments can still ensure accurate measurement, and can be very good to save. |
The wire harness hole
The hanging cable hole in the float water level meter base, can effectively prevent the passive floating cable and slipping, reduce the external environment caused by the measurement error, to deal with a variety of external harsh environmental conditions.
The instrument changes the water level with the float. Under the working condition, the float, the balance hammer are firmly connected with the suspension cable, and the suspension is suspended in the "V" groove of the water level wheel. Balance the hammer from the suspension of the suspension and balance the role of adjusting the weight of the float can make the float work on the normal waterline.
When the water level rises, the float produces upward buoyancy, so that the balance hammer pulls the cable to rotate the water level rotation for clockwise rotation, and the water level encoder displays the reading increase;
When the water level drops, the float sinks and pulls the suspension cable to move the water level wheel counterclockwise to rotate, and the water level encoder's display reading is reduced.
Qingyi float water level meter itself can be used independently of the measurement tool, comes with the LED screen can independently display the measurement depth, can also be transmitted through the 485 code to the LED screen to display real-time depth data.
Installed with RS485 digital communication interface (or 4-20mA) water level gauge, can be directly with the communications machine, computer or the corresponding instrument connected to form a hydrological automatic forecasting system.
Hydrological automatic forecasting system can also measure the dam infiltration line, see the dam water seepage situation.
Instrument built-in RS485 digital communication interface (optional), with location, gating function, to two-way way to send information over long distances, In a pair of twisted pair signal lines can drive or receive multiple water level (or gate) sensor, to achieve online multi-site networking capabilities.
Qingyi float water level meter can be collected by solar power, GPRS long-distance transmission of signals, transmission of different locations of the water level information, to achieve telemetry network function.
Name | Input pressure sensor | Float water level gauge | Ultrasonic water level sensor |
Advantage | Installation is simple, no mechanical action | High precision, no range limit, no water quality requirements, not affected by the weather | Easy installation, non-contact measurement |
Disadvantage | High water quality requirements | Mechanical aging, need protection | High environmental requirements, small range |